SOLARFLEX-X-PV1-F 2-STANDARD Cable


Solarflex-X PV1-F 2-standard

Temperature range :

-40 °C to +90 °C

Max. temp. at conductor +120 °C

Nominal voltage :

According to VDE U0/U 600/1000 V AC

1800 V DC conductor/conductor

AC test voltage :

6500 V, 50 Hz

Minimum bending radius :

Single 1.5 cable diameters

Multiple 10 cable diameters

Bare copper, Class 5, tinned, finely stranded according to DIN VDE 0295 class 5 and IEC 60228 cl. 5

Double-insulated

Insulation cross-linked special Polyolefin

Outer sheath cross-linked special Polyolefin

Sheath colour black

According to PV1-F requirement profile for PV cables DKE/VDE AK 411.2.3

VDE (Reg. 8266)

TÜV (2 PfG 1169/08.2007, R60025298)

RoHS and CE compliant

Approval: TÜV 2Pfg1169/08.2007

UV, ozone-resistant, weather-resistant,

Halogen-free

Abrasion and cut resistant

Relatively flexible

Easy to strip

Flame-resistant according to VDE 0482 Part 332-1-2, IEC 60332-1-2

Resistant to short circuits up to 200 °C thanks to double insulation, short circuit temperature 200 °C/5 sec.

Anticipated service life 25 years

The SOLARFLEX®-X PV1-F TWIN is used for cabling solar modules.


Part No. No. cores x cross-sec.
mm²
Outer Ø
app. mm
Cop. weight
kg / km
Weight
app. kg / km
Core / jacket
colour
705769 2 x 6 6.8 x 13.6 120.0 186.8 red, black/black

Cross-sections up to 2 x 16 mm² are available on request

Dimensions and specifications may be changed without prior notice.

Eland Part No. No. Of Cores Nominal Cross
Sectional Area
mm2
Nominal Overall Diameter
mm
Nominal Weight
kg / km
A6S10025 1 2.5 4.5 39
A6S10040 1 4 5.2 57
A6S10060 1 6 5.9 79
A6S1010 1 10 6.9 122
A6S1016 1 16 8.3 181
A6S1025 1 25 9.7 273
A6S1035 1 35 11 364
A6S1050 1 50 13.2 520
A6S1070 1 70 15.4 713
A6S1095 1 95 17.4 930
A6S1120 1 120 20.1 1191
A6S1150 1 150 22.5 1514
A6S1185 1 185 26 1828
A6S1240 1 240 26.8 2324

Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables


Nominal Cross Sectional Area
mm2
Maximum Resistance Of Conductor At 20℃
Metal-Coated Wires
ohms/Km
2.5 8.21
4 5.09
6 3.39
10 1.95
16 1.24
25 0.795
35 0.565
50 0.393
70 0.277
95 0.21
120 0.164
150 0.132
185 0.108
240 0.0817

The above table is in accordance with BS EN 60228 (previously BS 6360)

No. Of Cores Nominal Cross Sectional Area
mm2
Current Carrying Capacity
In Air
Amps
1 2.5 41
1 4 55
1 6 70
1 10 98
1 16 132
1 25 176
1 35 218
1 50 276
1 70 347
1 95 416
1 120 488
1 150 566
1 185 644
1 240 775

Based on a 60℃ ambient temperature

AIR TEMPERATURE UPTO 60 70 80 90 100 110
DE-RATING FACTOR 1.00 0.91 0.82 0.71 0.58 0.41