1 core Aluminium / Copper


1 core Aluminium / Copper

SIZE NOMINAL INSULATION THICKNESS NOMINAL OUTER SHEATH THICKNESS APPROX. OVERALL DIA OF CABLE ±2MM APPROX. WEIGHT OF CABLE MAX. CONDUCTOR DC RESISTANCE at 20° C NOMINAL CURRENT RATING
ALUMINIUM CONDUCTOR COPPER CONDUCTOR
A2XY 2XY ALUMINIUM COPPER GROUND AIR GROUND AIR
mm 2 mm mm mm Kg/Km 0hm/Km AMPS
1C X 4 0.70 1.80 7.50 70 90 7.410 4.610 40 35 49 46
1C X 6 0.70 1.80 8.00 80 115 4.610 3.080 49 46 61 58
1C X 10 0.70 1.80 9.00 90 170 3.080 1.830 64 63 81 78
1C X 16 0.70 1.80 10.00 120 230 1.910 1.150 83 80 105 107
1C X 25 0.90 1.80 12.00 160 330 1.200 0.727 100 112 132 144
1C X 35 0.90 1.80 13.00 200 420 0.868 0.524 120 137 157 176
1C X 50 1.00 1.80 14.50 250 560 0.641 0.387 140 165 187 212
1C X 70 1.10 1.80 16.50 330 755 0.443 0.268 170 209 227 269
1C X 95 1.10 1.80 18.00 450 1020 0.320 0.193 205 256 267 331
1C X 120 1.20 1.80 20.50 510 1255 0.253 0.153 235 305 305 385
1C X 150 1.40 2.00 22.50 630 1555 0.206 0.124 270 345 340 435
1C X 185 1.60 2.00 24.50 800 1900 0.164 0.0991 300 390 385 500
1C X 240 1.70 2.00 27.00 950 2450 0.125 0.0754 350 455 440 595
1C X 300 1.80 2.00 30.00 1150 3050 0.100 0.0601 400 525 500 680
1C X 400 2.00 2.20 33.80 1500 3850 0.0778 0.0470 460 615 560 785
SIZE NOMINAL INSULATION THICKNESS NOMINAL ARMOUR ALUMINIUM STRIP MINIMUM OUTER SHEATH THICKNESS APPROX. OVERALL DIAOF CABLE ±2MM APPROX. WEIGHT OF CABLE

MAX. CONDUCTOR DC RESISTANCE at 20° C NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR NOMINAL CURRENT RATING COPPER CONDUCTOR
A2XFaY 2XFaY ALUMINIUM COPPER GROUND AIR GROUND AIR
m m2

mm mm mm mm Kg/Km Ohm/Km AMPS
1C X 95 1.40 4X 0.80 1.40 20.00 570 1160 0.320 0.193 205 256 267 331
1C X 120 1 . 50 4X0.80 1.40 22.00 670 1420 0.253 0.153 235 305 305 385
1C X 150 1 . 70 4X 0.80 1.40 24.00 770 1690 0.206 0.124 270 345 340 435
1C X 185 1 . 90 4X 0.80 1.40 26.00 920 2050 0.164 0.0991 300 390 385 500
1C X 240 2.00 4X 0.80 1.40 29.00 1150 2600 0.125 0.0754 350 455 440 595
1C X 300 2.10 4X 0.80 1.56 31.50 1355 3200 0.100 0.0601 400 525 500 680
1C X 400 2.40 4X0.80 1.56 35.50 1730 4200 0.0778 0.0470 460 615 560 785
SIZE NOMINAL INSULATION THICKNESS NOMINAL DIA OF AL.ARMOUR WIRE MINIMUM OUTER SHEATH THICKNESS APPROX. OVERALL DIA OF CABLE ±2MM APPROX. WEIGHT OF CABLE MAX. CONDUCTOR DC RESISTANCE at 20° C NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR

NOMINAL CURRENT RATING COPPER CONDUCTOR
A2XWaY 2XWaY ALUMINIUM COPPER GROUND AIR GROUND AIR
m m2 mm mm mm mm Kg/Km Ohm/Km AMPS
1C X 4 1.00 1.40 1.24 10.50 130 150 7.410 4.610 40 35 49 46
1C X 6 1.00 1.40 1.24 11.00 140 170 4.610 3.080 49 46 61 58
1C X 10 1.00 1.40 1.24 12.00 170 250 3.080 1.830 64 63 81 78
1C X 16 1.00 1.40 1.24 13.50 225 320 1.910 1.150 83 80 105 107
1C X 25 1.20 1.40 1.24 15.00 270 425 1.200 0.727 100 112 132 144
1C X 35 1.20 1.40 1.24 16.00 320 530 0.868 0.524 120 137 157 176
1C X 50 1.30 1.40 1.24 18.00 400 700 0.641 0.387 140 165 187 212
1C X 70 1.40 1.40 1.24 20.00 500 930 0.443 0.268 170 209 227 269
1C X 95 1.40 1.60 1.40 22.00 650 1250 0.320 0.193 205 256 267 331
1C X 120 1.50 1.60 1.40 24.00 750 1490 0.253 0.153 235 305 305 385
1C X 150

1.70 1.60 1.40 26.00 870 1790 0.206 0.124 270 345 340 435
1C X 185 1 .90 1 . 60 1.40 28.00 1050 2160 0.164 0.0991 300 390 385 500
1C X 240 2.00 1.60 1.40 31.50 1250 2700 0.125 0.0754 350 455 440 595
1C X 300 2 .10 1 . 60 1.56 34.50 1550 3350 0.100 0.0601 400 525 500 680
1C X 400 2.40 2.00 1.56 38.00 1950 4380 0.0778 0.0470 460 615 560 785
  • -THE ABOVE DATA IS APPROXIMATE & SUBJECT TO MANUFACTURING TOLERANCE, 2. DELIVERY LENGTH TOLERANCE +/- 5%.