Johnson Premium (Double Sheathed)


Johnson Premium (Double Sheathed)

TYPES OF CABLES : SUBMERSIBLE FLEXIBLE FLAT CABLE (DOUBLE SHEATHED)
DESIGNATION : XLPE INSULATED (RESISTANCE TO OZONE & U.V. RAYS) AND WATER TIGHT DESIGN WITH MODIFIED POLYMERTPR SHEATHED FLAT FLEXIBLE EC GRADE COPPER CABLES
CABLE DESIGN: :
COPPER CONDUCTOR : ANNEALED COPPER WITH FLEXIBLE BUNCH EC GRADE COPPERAS PER CLASS 2 OR 5 (IS 8130)
INSULATION : XLPE (RESISTANCE TO OZONE &U.V. RAYS) DOUBLE INSULATED.
INNER SHEATH : REDUCED THERMAL EXPANSION WITH MODIFIED POLYMER
SHEATH : WEATHERING STABILITY WITH MODIFIEDTPR SHEATH
MECHANICAL PROPERTY (INSULATION-XLPE) : TENSILE STRENGTH12.5 N/MM2 (Min.), ELONGATION:200% (Min.)
MECHANICAL PROPERTY (SHEATH-TPR) : TENSILE STRENGTH12.5 N/MM2 (Min.), ELONGATION:150% (Min.)
TEMP. RANGE : (-20° C to + 90° C)
TEST VOLTAGE : 3 KV FOR 5 MINUTE (ELECTRICAL PROPERTY)
CORE COLOR DOUBLE INSULATED : 3 CORE: RED , YELLOW , BLUE
VOLUME RESISTIVITY INSULATION (ELECTRICAL PROPERTY) : 1X10 14(Min.) Ω-cm AT 27 CTEMP.
: 1X10 12 (Min.) Ω-cm AT 90° CTEMP.
REF. STD : IS 694 , IS 8130 , IS 7098-P-1
RATED VOLTAGE : 1100V
SHEATH COLOUR : GREEN
DESCRIPTION : JOHNSON CABLES INTRODUCES " JOHNSON PREMIUM" SUBMERSIBLE CABLE WITH PERFORMING INSULATION AND SHEATH. THIS IS A FLEXIBLE FLAT CABLE WITH LOW WATER ABSORPTION RATE FOLLOWING FEATURES.
CABLES FEATURES : - WATER TIGHT DESIGN WITH " RESISTANT WATER TREEING " PROPERTIES.
: - FLEXIBLE COPPER WITH DOUBLE SHEATHED
: - SHEATH RESISTANCE TO OZONE, U.V. RAYS, MOISTURE, OILAND CHEMICALS IN SOIL
: - REDUCED THERMAL EXPANSION AND GOOD WEATHERING STABILITY.
: - POLYMERS FOR ENHANCED ELECTRICAL PERFORMANCE.
: - HIGH DIELECTRIC VALUE INSULATION
: - VERY GOOD CURRENT CARRYING CAPACITY
ISO CERTIFICATION : ISO 9001:2015 , CE, RoHs , ISO 14001:2015 , IS0 45001:2018
PRODUCT CERTIFICATION : IS 694:2010 7098 P-1 , TUV RHEINLAND CERTIFICATE No. R 60160877
SIZE CABLE CLASS OF CONDUCTOR NOS.& DIA OF WIRE (MAX.) NOM. INSULATION THICKNESS NOM. SHEATH THICKNESS APPROX OVERALL DIMENSION (MM) MAX. D.C.C.R @ 20° C (COPPER) MAX. CURRENT CARRING CAPACITY
mm2 TYPE CLASS Nos./mm mm mm WIDTH HEIGHT Ω / km AMPS

3C X 1.5

FLAT -2X-YN

CLASS 2

22/0.3

0.70

1.00

11.30

4.90

12.1

18

3C X 2.5

FLAT -2X-YN

CLASS 2

36/0.3

0.70

1.10

13.40

5.80

7.41

22

3C X 4

FLAT-2X-YN

CLASS 5

56/0.3

0.70

1.20

15.80

6.60

4.95

31

3C X 6

FLAT -2X-YN

CLASS 5

84/0.3

0.70

1.30

18.60

7.80

3.30

38

3C X 8

FLAT -2X-YN

CLASS 5

112/0.3

0.70

1.40

21.40

8.80

2.48

44

3C X 10

FLAT -2X-YN

CLASS 5

140/0.3

0.70

1.50

23.00

9.30

1.91

50

3C X 12

FLAT -2X-YN

CLASS 5

168/0.3

0.70

1.60

25.20

10.20

1.61

57

3C X 16

FLAT -2X-YN

CLASS 5

224/0.3

0.70

1.70

28.40

11.20

1.21

65

3C X 25

FLAT -2X-YN

CLASS 5

354/0.3

0.90

2.10

35.40

14.20

0.780

100

3C X 35

FLAT -2X-YN

CLASS 5

495/0.3

0.90

2.20

38.60

15.40

0.554

120

3C X 50

FLAT -2X-YN

CLASS 5

703/0.3

1.00

2.40

45.50

17.90

0.386

150

  • - THE NUMBER OF SIRAND & ST RANDS DIAMETER SHALL BE SUCH THAT IT MEETS THE CONDUCTOR RESISTANCE AS PER RELEVANT STANDARD.
  • - THE ABOVE DATA IS INDICATIVE AND MAY BE REVISED WITHOUT PRIOR INFORMATION. JOHNSON CABLES WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF IN CORRECT APPLICATION.
  • - TOLERANCE: UP TO 4.0 SQ MM +/-0.5 MM. 6.0 SQ MM & 10 SQ MM +/-1.0 MM AND ABOVE 10 SQ MM +/-1.2 MM