SIZE | NOMINAL INSULATION THICKNESS | MINIMUM INNER SHEATH THICKNESS | MINIMUM OUTER SHEATH THICKNESS | APPROX. OVERALL DIAOF CABLE ±2MM | APPROX. WEIGHT OF CABLE | MAX. CONDUCTOR DC RESISTANCE at 20° C | NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR | NOMINAL CURRENT RATING COPPER CONDUCTOR | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
A2XY | 2XY | ALUMINIUM | COPPER | GROUND | AIR | GROUND | AIR | |||||
mm2 | mm | mm | mm | mm | Kg/Km | Ohm/Km | AMPS | |||||
3C X 4 | 0.70 | 0.30 | 1.80 | 13.00 | 200 | 270 | 7.41 | 4.61 | 35 | 31 | 44 | 39 |
3C X 6 | 0.70 | 0.30 | 1.80 | 14.00 | 240 | 350 | 4.61 | 3.08 | 44 | 41 | 55 | 50 |
3C X 10 | 0.70 | 0.30 | 1.80 | 15 .50 | 300 | 490 | 3.08 | 1.83 | 58 | 53 | 74 | 68 |
3C X 16 | 0.70 | 0.30 | 1.80 | 16.50 | 340 | 590 | 1.91 | 1.15 | 75 | 70 | 95 | 86 |
3C X 25 | 0.90 | 0.30 | 2.00 | 19.50 | 480 | 920 | 1.200 | 0.727 | 96 | 93 | 121 | 119 |
3C X 35 | 0.90 | 0.30 | 2.00 | 21.50 | 580 | 1230 | 0.868 | 0.524 | 116 | 116 | 146 | 147 |
3C X 50 | 1.00 | 0.30 | 2.00 | 24.00 | 760 | 1690 | 0.641 | 0.387 | 140 | 140 | 171 | 178 |
3C X 70 | 1.10 | 0.30 | 2.20 | 28.00 | 1020 | 2290 | 0.443 | 0.268 | 171 | 175 | 211 | 225 |
3C X 95 | 1.10 | 0.40 | 2.20 | 31.00 | 1250 | 3020 | 0.320 | 0.193 | 201 | 217 | 251 | 278 |
3C X 120 | 1.20 | 0.40 | 2.20 | 33.50 | 1520 | 3780 | 0.253 | 0.153 | 226 | 250 | 286 | 318 |
3C X 150 | 1.40 | 0.40 | 2.40 | 37.50 | 1920 | 4700 | 0.206 | 0.124 | 256 | 285 | 316 | 364 |
3C X 185 | 1.60 | 0.50 | 2.60 | 41.50 | 2390 | 5770 | 0.164 | 0.0991 | 286 | 330 | 356 | 421 |
3C X 240 | 1.70 | 0.50 | 2.80 | 46.50 | 3000 | 7400 | 0.125 | 0.0754 | 327 | 393 | 411 | 500 |
3C X 300 | 1.80 | 0.60 | 3.00 | 51.50 | 3750 | 9200 | 0.100 | 0.0601 | 371 | 453 | 461 | 572 |
3C X 400 | 2.00 | 0.60 | 3.20 | 58.00 | 4770 | 11600 | 0.0778 | 0.0470 | 429 | 529 | 521 | 660 |
SIZE | NOMINAL INSULATION THICKNESS | MINIMUM INNER SHEATH THICKNESS | NOMINAL ARMOUR STRIP | MINIMUM OUTER SHEATH THICKNESS | APPROX. OVERALL DIAOF CABLE ±2MM | APPROX. WEIGHT OF CABLE | MAX. CONDUCTOR DC RESISTANCE at 20° C | NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR | NOMINAL CURRENT RATING COPPER CONDUCTOR | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A2XFY | 2XFY | ALUMINIUM | COPPER | GROUND | AIR | GROUND | AIR | ||||||
mm2 | mm | mm | mm | mm | mm | Kg/Km | Ohm/Km | AMPS | |||||
3C x 10 | 0 . 70 | 0.30 | 4 X 0.80 | 1.24 | 17.00 | 500 | 670 | 3.08 | 1.830 | 58 | 53 | 74 | 68 |
3C X 16 | 0.70 | 0.30 | 4 X 0.80 | 1.24 | 17.00 | 540 | 850 | 1.910 | 1.150 | 75 | 70 | 95 | 86 |
3C X 25 | 0.90 | 0.30 | 4 X 0.80 | 1.40 | 20.00 | 770 | 1150 | 1.200 | 0.727 | 96 | 93 | 121 | 119 |
3C X 35 | 0.90 | 0.30 | 4 X 0.80 | 1.40 | 21.50 | 900 | 1450 | 0.868 | 0.524 | 116 | 116 | 146 | 147 |
3C X 50 | 1.00 | 0.30 | 4 X 0.80 | 1.40 | 24.50 | 1100 | 1850 | 0.641 | 0.387 | 140 | 140 | 171 | 178 |
3C X 70 | 1.10 | 0.30 | 4 X 0.80 | 1.56 | 29.00 | 1430 | 2550 | 0.443 | 0.268 | 171 | 175 | 211 | 225 |
3C X 95 | 1.10 | 0.40 | 4 X 0.80 | 1.56 | 31.00 | 1740 | 3300 | 0.320 | 0.193 | 201 | 217 | 251 | 278 |
3C X 120 | 1.20 | 0.40 | 4 X 0.80 | 1.56 | 33.50 | 2060 | 4000 | 0.253 | 0.153 | 226 | 250 | 286 | 318 |
3C X 150 | 1.40 | 0.40 | 4 X 0.80 | 1.72 | 37.50 | 2350 | 5000 | 0.206 | 0.124 | 256 | 285 | 316 | 364 |
3C X 185 | 1.60 | 0.50 | 4 X 0.80 | 1.88 | 42.00 | 2850 | 6000 | 0.164 | 0.0991 | 286 | 330 | 356 | 421 |
3C X 240 | 1.70 | 0.50 | 4 X 0.80 | 2.04 | 46.50 | 3600 | 7700 | 0.125 | 0.0754 | 327 | 393 | 411 | 500 |
3C X 300 | 1.80 | 0.60 | 4 X 0.80 | 2.20 | 51.50 | 4400 | 9450 | 0.100 | 0.0601 | 371 | 453 | 461 | 572 |
3C X 400 | 2.00 | 0.60 | 4 X 0.80 | 2.36 | 58.00 | 5500 | 12200 | 0.0778 | 0.0470 | 429 | 529 | 521 | 660 |
SIZE | NOMINAL INSULATION THICKNESS | MINIMUM INNER SHEATH THICKNESS | NOMINAL ARMOUR WIRE | MINIMUM OUTER SHEATH THICKNESS | APPROX. OVERALL DIA OF CABLE ± 2 MM | APPROX. WEIGHT OF CABLE | MAX. CONDUCTOR DC RESISTANCE at 20° C | NOMINAL CURRENT RATING ALUMINIUM CONDUCTOR | NOMINAL CURRENT RATING COPPER CONDUCTOR | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A2XWY | 2XWY | ALUMINIUM | COPPER | GROUND | AIR | GROUND | AIR | ||||||
mm2 | mm | mm | mm | mm | mm | Kg/Km | Ohm/Km | AMPS | |||||
3C X 4 | 0.70 | 0.30 | 1.40 | 1.24 | 14.50 | 450 | 520 | 7.410 | 4 .61 | 35 | 31 | 44 | 39 |
3C X 6 | 0.70 | 0.30 | 1.40 | 1.24 | 15.50 | 500 | 620 | 4.610 | 3.08 | 44 | 41 | 55 | 50 |