Johnson Gold E-Beam


Johnson Gold E-Beam

APPLICABLE STANDARD : IS 694:2010
CONDUCTOR : THE CONDUCTORS DRAWN FROM 99.97 % BRIGHT ELECTROLYTIC GRADE COPPER WITH MORE THAN 100% CONDUCTIMITYARE. ANNEALED AND BUNCHED TOGETHER.
TYPEEBXL HRFR PVC COMPOUND : THE BUNCH CONDUCTORS ARE INSULATED WITH SPECIALLY FORMULATED E-BEAMXL HEAT RESISTANCE FLAME RETARDANT PVC COMPOUND WITHA HIGH INSULATION RESISTANCE VALUE THESE CABLES ARE INSULATED WITH sPECIALLY FORMULATED & IN-HOUSE MANUFACTURED FR/LsOH/FRLS-H cOMPOUND AND INCORPORATING EB TECHNOLOGY THAT ENHANCES ELECTRICAL, THERMAL, FIRE AND MECHANICAL PROPERTY OF JOHNSON GOLDE-BEAM WIRE &CABLES.
OPERATING TEMPERATURE RANGE : UPTO TO MAX. +105°C
COLOUR : RED, YELLOW, BLUE, BLACK, GREEN, GRAY (AND ALSO OTHER COLOUR REQUEST ON CUSTOMER)
MARKING : THE CABLES ARE PRINTED WITH GENERIC MARKING" JOHNSON GOLDE-BEAM"
JOHNSON GOLD E-BEAM FEATURES : .MANUFACTURED FROM BRIGHT ANNEALED 99.97 % PURE COPPER CONDUCTORS THESE CABLES HAVE LOW CONDUCTOR RESISTANCE RESULTING IN POWER SAVING.
.THESE WIRES ARE INSULATED WITH A SPECIAL GRADE E-BEAM XL HRFR PVC COMPOUND FORMULATED AND MANUFACTURED IN-HOUSE. THE INSULATION IS FAR SUPERIOR IN TERMS OF CRITICAL OXYGEN AND TEMPERATURE INDEX.
.ALSO IN LIGHT TRANSMISSION AND ACID GAS GENERATION. THE SKIN COLORATION OFFER HIGH INSULATION RESISTANCE AND LONG LIFE.
.CONTINUOUSLY WITHSTAND INSULATION HIGHER CONDUCTOR TEMPERATURE OF UP TO 105 DEGREE C COMPARED TO CONVENTION CABLES WHICH ARE CAPABLE TO wORK AT MAXIMUM 7O DEGREE.
.SUPERIOR ABRASION PROPERTIES REDUCES THE DAMAGE TO WIRE INSULATION DURING INSTALLATION.
.JOHNSON GOLD E-BEAM" WIRES & CABLES TO CARRY DOUBLE THE RATED CURRENT (OF CONVENTIONAL WIRES) BESIDES IMPROVING THE CABLE LIFE MORE THAN DOUBLE.
.HIGH TEMPERATURE WITHSTANDING CAPACITY UP TO 105°C.
.HIGHER THERMALAGEING AND ENDURANCE.
.IMPROVED FLAME RETARDANT PROPERTIES COMPARED TO SPECIFIED PROPERTIES.
.HIGH CURRENT CARRYING CAPACITY.
LONGEROPERATING LIFE SPAN.
. OXYGEN INDEX:>29%, TEMPERATURE INDEX: 250%, SMOKE DENSITY RATING: 75%, ACID GAS GENERATION: 20%, SERVICE LIFE: >50 Years
TECHNICAL FEATURE : OXYGEN INDEX: >29%, TEMPERATURE INDEX: 250%6, SMOKE DENSITY RATING: 75%, ACID GAS GENERATION:20%, SERVICE LIFE: >50 Years
PRODUCT CERTIFICATION : IS 694 : 2010 7098 P-1 , TUV RHEINLAND CERTIFICATE No. R 60160877
NOMINAL CROSS SECTIONAL AREA NUMBER/ NOMINAL DIA OF WIRES* (NOM.) NOMINAL THICKNESS OF INSULATION APPROX OVERALL DIA (+/-0.2 mm) MAXIMUM DC RESISTANCE OF CONDUCTOR AT 20° C MAX. CURRENT RATING IN AMPS
IN CONDUIT/ TRUNKING UNENCLOSED-CLIPPED DIRECTLY TO SURFACE OR ON CABLE TRAY
0.75 24 / 0.20 0.6 2.30 26.00 9 14
1 32 / 0.20 0.6 2.50 19.50 16 24
1.5 30 / 0.25 0.7 2.85 13.30 20 32
2.5 50 / 0.25 0.8 3.40 7.98 27 44
4 56 / 0.30 0.8 4.10 4.95 36 58
6 84 / 0.30 0.8 5.10 3.30 47 74
  • - CLASS 5 CONDUCTOR
  • - THE NUMBER OF WIRES AND DIAMETER MENTIONED IN THE TABLE ARE APPROXIMATE AND NOMINAL, HOWEVER THEY SHALL MEET THE REQUIREMENTS OF. CONDUCTOR RESISTANCE AS PER STANDARDS. IS 8130
  • - THE ABOVE DATA IS INDICATIVE AND MAY BE REVISED WITHOUT PRIOR INTIMATION, JOHNSON CABLES WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF INCORRECTAPPLICATION.
  • - AVAILABLE IN LSOH AND FRLS-H INSULATIONAS PER CUSTOMER DEMAND.